Fluidics calculator: Kv value, flow rate and pressure drop

Calculate the required Kv value, the flow rate or the pressure drop of a valve for liquids and gases. The calculation follows the simplified standard formulas (IEC 60534) and is suited for an initial sizing.

Kv
Equivalent Cv value
Flow velocity in the pipe
Guide values based on simplified IEC 60534 formulas: liquids Kv = Q · √(ρ/1000 / Δp), gases (subcritical) Qn = 514 · Kv · √(Δp · p2 / (ρn · T)). Viscosity, cavitation, flashing, pipe losses and installation factors are not taken into account. Gas velocity refers to the inlet condition. Contact us for an exact sizing. Non-binding.

The Kv value states how much water (m³/h) flows through the valve at 1 bar pressure drop. Suitable valves can be found in our solenoid valves and process and control valves. Contact us and we will size the valve together with you.